Fuel-level Sensors
Our high-precision capacitive fuel-level sensors are exceptionally robust, extremely precise (99.5% accuracy), totally reliable (highest possible ingress protection rating of IP69k) and super-safe. They deliver consistently high accuracy in even the harshest conditions.
Omnicomm’s digital data transmission protocol has become the de facto industry standard in capacitive fuel-level sensors globally.
The sensors work both with OMNICOMM tracking equipment and are compatible with the most popular vehicle trackers and tracking platforms.
Omnicomm’s sensors include the adaptable OMNICOMM LLS 5 and adaptable explosion-proof OMNICOMM LLS-Ex 5, digital OMNICOMM LLS 4 and OMNICOMM LLS-AF 4 with analogue and frequency-modulated output.
Omnicomm LLS5 digital fuel level sensor with auto-calibration function for measuring the level in fuel tanks of vehicles and stationary fuel storage facilities
Constantly changing fuel characteristics can dramatically affect the accuracy of fuel measurements. Factors as diverse as oil manufacturing methods, additives used in gasoline production, switching from winter to summer fuel and fuelling at different stations affect the physical characteristics of filled fuel. Capacitive sensors measure a specific characteristic (dielectric permittivity) that can differ significantly from the dielectric permittivity of the fuel used during calibration – causing errors in fuel-level calculations of up to 30%.
OMNICOMM LLS 5 uses OMNICOMM's unique Fuelscan® technology to guarantee unprecedented accuracy of 99.5% in all conditions. Using measurements from an additional probe in the sensor to compare filled fuel characteristics with the fuel used for calibration and calculate measurements accordingly, this sensor sets a new industry standard and is twice as accurate as regular capacitive fuel-level sensors.
OMNICOMM LLS 5 reduces maintenance and re-calibration needs with the ability to compensate for errors in initial calibration, an issue that affects 20% of installed sensors. It provides precise fuel accounting for fleet owners and builds customer loyalty for installation partners who can confidently deliver on promises of accuracy.
The sensor has the highest possible ingress protection rating (IP69K), allowing high-pressure hot-water washes.
Error in measurement, % | ± 0,5 |
Output | RS-232, RS-485 |
Power supply voltage, V | 7...75 |
Ingress protection rating | IP69k |
Dielectric strength of galvanic isolation, min, V | 2500 |
Operating temperature, C | - 60 ... +85 |
Temperature measuring range, C | - 40 ... + 80 |
Resolution, bit | 12 |
Output range of readings corresponding to the maximum value of measured level |
1...4095 |
Output range of readings corresponding to the minimum value of measured level |
0...4094 |
Omnicomm LLS-Ex 5 digital fuel level sensor for measuring the level in fuel tanks of vehicles and stationary fuel storage facilities, which are subject to equipment explosion protection requirements
OMNICOMM LLS-Ex 5 is the explosion-proof version of OMNICOMM LLS 5, using OMNICOMM's auto-adjusting Fuelscan® technology to guarantee unprecedented accuracy of 99.5% in all conditions.
Factors as diverse as oil manufacturing methods, additives used in gasoline production, switching from winter to summer fuel, fuelling at different stations and switching from diesel to gasoline in stationary storage tanks affect the physical characteristics of filled fuel. Capacitive sensors measure a specific characteristic (dielectric permittivity) that can differ significantly from the dielectric permittivity of the fuel used during calibration – causing errors in fuel-level calculations of up to 30%.
Using measurements from an additional probe in the sensor to compare filled fuel characteristics with the fuel used for calibration and calculate measurements accordingly, this sensor sets a new industry standard and is twice as accurate as regular capacitive fuel-level sensors. The sensor reduces maintenance and re-calibration needs with the ability to compensate for errors in initial calibration, an issue that affects 20% of installed sensors. It provides precise fuel accounting for fleet owners and builds customer loyalty for installation partners who can confidently deliver on promises of accuracy. OMNICOMM LLS-Ex 5 features additional explosion protection and is designed for use in equipment operating in potentially hazardous areas. It can be installed in mobile and stationary fuel tanks and storages up to 6 meters in height.
Power protection unit BIS-MX
Device for protecting intrinsically safe circuits from high voltages and powering fuel level sensors Omnicomm LLS-Ex 5
Error in measurement, % | ± 0,5 |
Output | RS-232, RS-485 |
Power supply voltage, V | 7...60(through BIS-MX) |
Ingress protection rating | IP69k |
Dielectric strength of galvanic isolation, min, V | 7000 |
Operating temperature, C | - 60 ... +85 |
Temperature measuring range, C | - 40 ... + 80 |
Resolution, bit | 12 |
Output range of readings corresponding to the maximum value of measured level |
1...4095 |
Output range of readings corresponding to the minimum value of measured level |
0...4094 |
Omnicomm LLS 4 digital fuel level sensor for measuring the level in vehicle fuel tanks and stationary fuel storage facilities
The new Omnicomm LLS 4 is extremely tough, accurate and reliable with increased all-round protection, including against electrostatic, electromagnetic and conducted interference.
The sensor head is designed to improve shock resistance while its compact size facilitates installation even in units very close to the fuel tank. The new enhanced cable connection slot with over-moulding is ultra-resistant to humidity, providing protection even when subjected to high-pressure washes.
The LLS 4 has an improved ingress protection rating of IP-69K.
Error in measurement, % | ± 1,0 |
Output | RS-232, RS-485 |
Power supply voltage, V | 7...80 |
Ingress protection rating | IP69k |
Dielectric strength of galvanic isolation, min, V | 1500 |
Operating temperature, C | - 60 ... +85 |
Temperature measuring range, C | - 40 ... + 80 |
Resolution, bit | 12 |
Output range of readings corresponding to the maximum value of measured level |
1...4095 |
Output range of readings corresponding to the minimum value of measured level |
0...1023 |
Omnicomm LLS-AF 4 analog fuel level sensor for measuring the level in vehicle fuel tanks
We’ve reworked the hardware design of the new Omnicomm LLS-AF4 to achieve even greater stability. This seriously robust and efficient sensor is intended for use with cheaper GPS Trackers that don’t yet support connection of the LLS 4 digital sensor over RS232/RS485 interfaces.
The LLS-AF 4 has analog and frequency-modulated outputs protected by galvanic insulation and works independently throughout the range of power supply voltage. It is equipped with a ‘Tough Road Conditions’ mode, as well as an enhanced cable connection slot that is ultra-resistant to humidity.
The LLS-AF 4 has an improved ingress protection rating of IP-69K.
Error in measurement, % | ± 1,0 |
Output | Analog / Frequency |
Power supply voltage, V | 7…45 |
Ingress protection rating | IP69k |
Dielectric strength of galvanic isolation, min, V | 250 |
Operating temperature, C | - 40 ... +80 |
Temperature measuring range, C | - 40 ... + 80 |
Resolution, bit | 12 |
Output range of readings corresponding to the maximum value of measured level | 5…20V / 100...2000Hz |
Output range of readings corresponding to the minimum of measured level | 0…15V / 30…1900Hz |
READY TO BUY?
We are a global presence, with a local touch. Our products are distributed to over 110 countries on five continents via our worldwide partner network.
Our trusted partners offer our customers a full range of services, from basic product delivery and installation to value-added consulting and business intelligence analytics to transform your business.
Fill in the form below and we will connect you with the local partner that can best serve your needs.